Once the aluminum scaffolding tower is set up, it must be inspected by a competent person before it can be used. A study should be performed if there are significant additions, removals or changes. Be sure to check all aluminum scaffolding ladder protection materials. The check includes the following:
- Check if it vertical and square and all the horizontal braces and platforms are level.
- Check for the outriggers or stabilizers to be correctly positioned and secured.
- Check that all base plates or castor wheels are fully in contact with the ground, including those on stabilizers or outriggers. All castors should be properly locked.
- Check for the spigot and socket joint locks holding the frames together are secured or no.
- Check for all bracing members if they are located exactly where the supplier wanted or not.
- Check for all the guardrails and toe boards to be in the position as required.
- Check for all the access stairways/ladders to be in position and are firmly located.
- Aluminum Scaffolding Tower usage should be strictly avoided in the vicinity of live electrical apparatus or near unguarded machinery.
- Ensure the covering of any holes, ducts, pits or gratings present.